Tech Center

HPLC Q&A
HPLC Introduction
Fittings Primer
Materials Guide
Information Exchange
Conversion Tools
Standard Port Drawings


Perlast® Extended Properties

Physical Properties Unit Methods   Value
Hardness (points) °IRHD ASTM D 1415 (=ISO 48) 69
Tensile Strength MPa ASTM D 412 (=ISO 37) 9.0
Elongation at Break % ASTM D 412 (=ISO 37) 190
100% Modulus MPa ASTM D 412 (=ISO 37) 4.0
         
Compression Set,
Method B:
Unit Methods   Value
24 hours at 200° C (392° F) % ASTM D 395 (=ISO 815) 21
         
Heat Resistance: Unit Methods   Value
72 hours at 250° C (482° F)   ASTM D 573 (=ISO 188)  
Hardness change (points) °IRHD ASTM D 1415 (=ISO 48) -7
Tensile strength change % ASTM D 412 (=ISO 37) 3.5
Elongation at break change % ASTM D 412 (=ISO 37) +12
         
Low Temperature Properties: Unit Methods   Value
TR10 °C (°F) ASTM D 1329   -12 (-4)

Special Notes
FIRE HAZARD: Ignition temperature >400° C (750° F).

Thermal decomposition will generate hydrogen fluoride, fluorinated hydrocarbons, carbon monoxide and carbonyl fluoride. In the event of fire, fire fighters must wear self-contained breathing apparatus and a protective suit. Extinguish with water, foam, carbon dioxide or dry chemical. Neutralise any refuse from a fire involving perfluoroelastomer with calcium hydroxide solution and wear Neoprene ® gloves when handling.


Copyright © IDEX Corporation 2010.
IDEX Health & Science is a Unit of IDEX® Corporation. | Privacy Policy