Tech Center

HPLC Q&A
HPLC Introduction
Fittings Primer
Materials Guide
Information Exchange
Conversion Tools
Standard Port Drawings


PEEK™ Extended Properties

General   Methods Units  
Relative Density (Crystalline)
(Amorphous)
ASTM D792
ASTM D792
-
-
1.30
1.26
Typical Level of Crystallinity   - % 30-35
Mold Shrinkage   - % 1.0-1.8
Water Absorption 24 hr. @ 73°F
Equilibrium @ 73°F
ASTM D570
ISO R62A
%
%
0.50
0.50
         
Mechanical   Methods Units  
Tensile Strength @ 73°F (yield)
@ 482°F (yield)
ASTM D638 (5mm/min)
ASTM D638 (5mm/min)
psi
psi
14,000
1,750
Elongation at Break @ 73°F ASTM D638 (5mm/min) % >50
Elongation at Yield @ 73°F ASTM D638 (5mm/min) % 4.9
Flexural Modulus: @ 73°F
@ 248°F
@ 482°F
ASTM D790
ASTM D790
ASTM D790
psi
psi
psi
594,000
580,100
43,500
Flexural Strength @ 73°F
@ 248°F
@ 482°F
ASTM D790
ASTM D790
ASTM D790
psi
psi
psi
24,650
14,500
1,800
IZOD Impact Strength @ 73°F
Notched
Unnotched
ASTM D256 ft.-lb./in.
1.57
No Break
         
Thermal   Methods Units  
Melting Point   DSC °F (°C) 644(340)
Glass Transition Temperature, Tg (onset value)   DSC °F (°C) 289(143)
Melt Flow Index 400°C/2.16 kg ASTM D1238 g/10 min. 4
Coefficient of Thermal Expansion: <Tg
>Tg
ASTM D696
ASTM D696
10-5°F-1 2.6
6
Heat Deflection Temperature, 264 psi   ASTM D648 °F (°C) 320(160)
UL Continuous Use Temperature Mechanical
Electrical
    464(240)
500(260)
         
Sterilization   Methods Units  
200 steam cycles at 280°F short time, 1/8" thick - - No Effect
1000 Mrads gamma radiation   - - No Effect
Chemicals (ethylene oxide, etc.)   - - No Effect
Heat up to 500°F   - - No Effect
         
Electrical   Methods Units  
Dielectric Strength (50µ film)   ASTM D149 KV/cm 190
Dielectric Constant 50Hz-10kHz, 0-300°F
50Hz, 392°F
  - 3.20-3.30
4.50

Special Notes
Chemicals which interact with PEEK polymer are not pH dependent; rather, interaction is more determined by other physical properties of the chemical(s) in question. Not recommended for use with nitric acid; sulfuric acid; halogenated acids, such as hydrofluoric, hydrobromic, and hydroiodic acids (hydrochloric acid is approved for most applications); and pure halogenated gases. Additionally, due to a swelling effect, be cautious in using the following solvents with PEEK tubing: methylene chloride, THF, and DMSO.


Copyright © IDEX Corporation 2010.
IDEX Health & Science is a Unit of IDEX® Corporation. | Privacy Policy