Perlast® Extended Properties
| Physical Properties |
Unit |
Methods |
|
Value |
|
| Hardness (points) |
°IRHD |
ASTM D 1415 |
(=ISO 48) |
69 |
| Tensile Strength |
MPa |
ASTM D 412 |
(=ISO 37) |
9.0 |
| Elongation at Break |
% |
ASTM D 412 |
(=ISO 37) |
190 |
| 100% Modulus |
MPa |
ASTM D 412 |
(=ISO 37) |
4.0 |
| |
|
|
|
|
Compression Set,
Method B: |
Unit |
Methods |
|
Value |
|
| 24 hours at 200° C (392° F) |
% |
ASTM D 395 |
(=ISO 815) |
21 |
| |
|
|
|
|
| Heat Resistance: |
Unit |
Methods |
|
Value |
|
| 72 hours at 250° C (482° F) |
|
ASTM D 573 |
(=ISO 188) |
|
| Hardness change (points) |
°IRHD |
ASTM D 1415 |
(=ISO 48) |
-7 |
| Tensile strength change |
% |
ASTM D 412 |
(=ISO 37) |
3.5 |
| Elongation at break change |
% |
ASTM D 412 |
(=ISO 37) |
+12 |
| |
|
|
|
|
| Low Temperature Properties: |
Unit |
Methods |
|
Value |
|
| TR10 |
°C (°F) |
ASTM D 1329 |
|
-12 (-4) |
| Special Notes |
|
FIRE HAZARD: Ignition temperature >400° C (750° F).
Thermal decomposition will generate hydrogen fluoride, fluorinated hydrocarbons, carbon monoxide and carbonyl fluoride. In the event of fire, fire fighters must wear self-contained breathing apparatus and a protective suit. Extinguish with water, foam, carbon dioxide or dry chemical. Neutralise any refuse from a fire involving perfluoroelastomer with calcium hydroxide solution and wear Neoprene ® gloves when handling. |
|
| |
Copyright © IDEX Corporation 2010.